Researchers in the Molecular Imaging Instrumentation Laboratory at Stanford University have developed a PET (positron emission tomography) detector and front end readout assembly that can operate in a high field MRI (magnetic resonance imaging) system.
Stanford researchers have developed a method which can simultaneously observe two positron emitting isotopes using two distinct molecular probes and a modified PET scanner. This system enables the simultaneous observation of two different molecular processes.
A Stanford researcher has developed two advanced approaches for the positron sensitive high-energy photon sensor technology for Positron Emission Tomography (PET).
Stanford researchers have prototyped a system to enhance the sensitivity of triple coincidences for multi-isotope PET by adding an extra detector dedicated for the detection of the third prompt gamma in coincidence with the annihilation photons.
Stanford researchers have patented a novel concept for a position sensitive high-energy photon sensor device for high resolution radiation imaging that can enhance capabilities of Positron Emission Tomography (PET).
Current techniques for reconstructing images in positron emission tomography (PET) cannot correctly use events in which at least one photon of a pair has scattered in tissue (also known as scatter coincidence events).
Stanford researchers at the Pratx Lab have developed a new trajectory reconstruction method for tracking moving sources labeled with positron-emitting radionuclides using PET.
Stanford Researchers have patented a method and apparatus for detecting ionizing radiation, that, if successful, would achieve a coincidence time resolution 100x better than current positron emission tomography (PET) detectors.
Stanford researchers at the Rao Lab have developed apoptosis imaging probes with an improved new molecular structure enabling high sensitivity and stability with better performance in vivo.
Stanford researchers have invented a decoder for multiplexed readouts of imaging arrays that optimizes the signal-to-noise ratio (SNR) of the decoded detector pixel signals.
Researchers in the Molecular Imaging Instrumentation Laboratory at Stanford University have developed methods to improve the image quality of tomographic image reconstruction, including positron emission tomography (PET).
Dr. Sanjiv Gambhir and colleagues have developed positron emission tomography (PET) tracers to clinically image bacterial infection. Despite significant developments in the microbiology of infection, bacterial infections remain a major health issue.